MIL-C-60898/9
(MU)
4.
QUALITY
ASSURANCE
PROVISIONS
4.1.
General. The quality assurance provisions of MIL-C-
60898 shall apply to the assembly covered by this detail
specification.
4.2
First
article
inspection.
As
specified
in
MIL-C-60898.
4.3
Control
test
sample.
As
specified
in
MIL-C-60898.
4.4 Functional
tests. The following characteristics shall
be 100 percent
tested in accordance with the applicable
test
method.
Characteristic
Requirement
Procedure
4.5.2.1
100
Conditions of operation
3.4.1
101
Pin 19 output
4.5.2.2
3.4.2
102
Pin 23 output
4.5.2,3.
3.4.3
4.5.2.4
103
Pin 9 output
3.4.4
104
Pin 17 output
4.5.2.5
3.4.5
105
Diodes, reverse
4.5.2.6
current
3.4.6
106
Diodes, forward drop
4.5.2.7
3.4.7
4.5.2,8
107
Resistance
3.4.8
4.4.1
Inspection
equipment.
As
specified
in
MIL-C-60898
and 4.4.1.1.
4.4,1.1 Test equipment,
In conjunction with 4.4.1, the follow-
ing test equipment shall be utilized in the performance of the
applicable tests as specified in 4,5,
Item
Description
+22.0
0.1 vdc nominal voltage
POWER SUPPLY
1.
500ma ; or greater, ripple
with
less than 100 mv, voltage adjust-
able to +30.0 vdc
2.
POWER
SUPPLY
-22.00
0.10 vdc with 500ma;
or
greater,
ripple less than 100
mv
3*
POWER
SUPPLY
o - 30 vdc, O - 1.5 ampere; current
and voltage adjustable; ripple less
than 1 percent of output.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business