MIL-G-50351A (AR)
4.2 Classification of inspections. The inspection
requirements specified herein are classified as follows:
First article inspection (see 4.3).
a.
Quality conformance inspection (see 4.4).
b.
c.
Special sampling inspection (see 4.5).
4.2.1 Inspection conditions. Unless otherwise specified,
all examinations and tests shall be conducted at the following
standard ambient conditions:
to
Temperature
a.
90% RH Max.
Relative humidity
b.
28 to 32 inches Hg
Pressure
c.
4.3
First article inspection.
The contractor shall submit a first
4.3.1 Submission.
article sample as designated by the Contracting Officer for
The first
evaluation in accordance with provisions of 4.3.2.
article sample shall consist of the assemblies, components and
test specimens listed below in the quantities indicated.
Drawing
Quantity
Name
3
10558216
Fine Pulse Delay Assembly
As determined by the
4.3.2 Inspections to be performed.
Government, the first article assemblies, components and test
specimens may be subjected to any or all of the examinations and
tests specified in this detail specification and be inspected for
compliance with any or all requirements of the applicable
drawings.
If any assembly, component or test
4.3.3 Rejection.
specimen fails to comply with any of the applicable requirements,
the first article sample shall be rejected. The Government
reserves the right to terminate inspection upon any failure of an
assembly, component or test specimen to comply with any of the
requirements.