MIL-G-50351A (AR)
4.6.2.2 Contractor design. The contractor shall design and
supply inspection equipment compatible with the "Methods of
Inspection" specified in 4.7 of this specification and with the
component inspection procedures specified in "Examination and
"Test Facilities" requirements of MILF-13926 wherever Government
Since tolerance of test
designs are not specified (see 4.6.2.1).
equipment is normally considered to be within 10 percent o-f the
product tolerance for which it is intended, this inherent error
in the test equipment design must be considered as part of the
prescribed product tolerance limit. Thus, concept, construction,
materials, dimensions, and tolerances used in the design of test
equipment shall be so selected and controlled as to ensure that
the test equipment will reliably indicate acceptability of a
product which does not exceed 90 percent of the prescribed limit
and permit positive rejection when nonconforming. Construction
shall be such as to facilitate routine calibration of test
Contractor inspection equipment designs shall be
equipment.
submitted for approval in accordance with 6.3.
4.6.2.3 Test equ ipment.
In conjunction with 4.6.2.1 and
4.6.2.2, the standard test equipment listed in Table IV (Test
equipment list) shall be utilized in the performance of the
applicable test methods of inspection as specified in 4.7.
Test equ ipment list.