MIL-G-50351A (AR)
2.2 Order of precedence.
In the event of a conflict
between the text of this document and the references cited
Nothing in
herein, the text of this document takes precedence.
this document, however, supersedes applicable laws and
regulations unless a specific exemption has been obtained.
REQUIREMENTS
3.
3.1 Materials. Materials shall be in accordance with the
applicable drawings and specifications.
3.2 Components and assemblies. The components and
assemblies shall comply with all requirements specified on
Drawing 10558216, all associated drawings, and with all
requirements specified in applicable specifications and
Where applicable, the fine pulse delay assembly shall
standards.
meet the requirements of MILF-13926 as follows:
a.
Dimensions and tolerances.
Inorganic protective surface finishings.
b.
Part identification and marking.
c.
d.
Workmanship.
Environmental se rvice conditions.
3.3
The fine pulse delay assembly shall not
3.3.1 Vibration.
suffer damage and shall meet the requirements of 3.4 and 3.5
after exposure to sinusoidal vibrations, in each of three
mutually perpendicular axes, as specified in MIL-T-28800 for Type
I, Class 3, Style F test equipment.
The fine pulse delay assembly shall not
3.3.2 Shock .
suffer damage and shall meet the requirements of 3.4 and 3.5
after exposure to a total of 18 impulse shocks consisting of
10%, 11 milliseconds
10%,
three shock impulses of 15 g's
half-sine wave applied in each direction of 3 mutually
perpendicular axes.
3.3.3 Altitude operating. The fine pulse delay assembly
shall meet the requirements of 3.4 and 3.5 during and after
exposure to barometric pressure encountered at 10,000 feet above
sea level (20.6 inches of Hg).
3