3.3.1.1.3.2 Open circuit detection. With input power
applied, the power switch on, panel switches S1 through S83 in the
normal position, and pins 1 through 83 on connector 15J1
successively grounded, the continuity lamp shall not light. The
continuity lamp shall light under the above conditions when
switches S1 through S83 are individually set to the test position
setting of each panel switch (A failure to illuminate the
continuity lamp shall indicate an open conductor).
Interlock test switch indicator. with input
3.3.1.1.4
power applied, the power switch on, and pins 84 and 85 of 15J1
connected, the interlock test switch indicator lamp will be
When the interlock test switch is depressed the
illuminated.
indicator lamp will be extinguished.
3.3.1.1.5 Input power .
The assembly shall operate over an input
power range of 18 to 30V dc.
3.3.1.2 Insulation resistance. All insulation between
ungrounded circuits and ground, and between isolated circuits
shall have a minimum resistance of 10 megohms with 500V dc applied.
3.3.1.3 Dielectric strength. The dielectric strength of t-he
electrical wiring within the assembly shall withstand 2000 volt
root mean square (V rms) at a frequency of 60 Hertz (Hz) for a
period not less than 5 seconds.
3.3.1.4 Fungus resistance. All nonmetallic materials shall
be inherently fungistatic or treated to resist fungus growth
except when used for components of potted or otherwise moisture
sealed assemblies.
3.3.2
Physical
characteristics.
3.2.2.1
Physical characteristics. The assembly shall be
in accordance with Drawing 11733300 and drawings referenced therein.
3.3.2.2 Power cables.
Power cables shall be in accordance
with drawings 11732468 and 11732558.
3.3.2.3 Test interconnection cables.
Cables used to
interconnect the assembly with computer, rangefinder and
Tank Thermal Sight Cables shall be in accordance with drawings
11747425, 11747426, 11747427 and 11747428.
3.3.2.4 Ammo select cable. The ammo select cable shall be
in accordance with drawing 11742469.
3.3.2.5 Shorting connectors.
The shorting connectors, used
to complete test circuits, shall be in accordance with drawings
11732556, 11747429, 11747430, 11747431, 11747432, 11747433 and
11747434.