MIL-C-60898/11
(MU)
QUALITY
ASSURANCE
PROVISIONS
4.
4.1 General, The quality assurance provisions of MIL-C-60898
shall apply to the assembly covered by this detail specification,
As
specified
in
MIL-C-60898.
4.2'
First
article
inspection.
As
specified
in
MIL-C-60898.
4.3
Control
test
sample.
4.4
Functional
tests.
The following characteristics
shall
be
100
percent tested in
accordance with MIL-C-60898.
Procedure
Requirement
Characteristic
3.4.1
4.5.2.1
Diode networks
3.4.1.1
4.5.2.1.1
101
Pin 6 output
4.5.2 .1.2
3.4.1.2
102
Pin 12 output
4.5.2.1.3
3.4.1.3
103
Pin 9 output
4.5.2.1.4
3.4.1.4
104
Diodes, reverse current
4.5.2.1.5
3.4.1.5
105
Diodes, forward drop
4.5.2.2
3.4.2
106
Capacitance
4.5.2.3
3.4.3
107
Resistance
4.5.2.4
3.4.4
108
Pulse transformers
As
specified
in
MIL-C-60898
and
4.4.1
Inspection
equipment.
as below in 4.4.1.1.
In conjunction with 4.4.1, the follow-
4.4.1.1
Test
equipment.
ing equipment shall be utilized in the performance of the appli-
cable tests as specified in 4.5.
Description
Item
+10.00
0.05 vdc, no less
POWER
SUPPLY
1.
than 500 ma, no greater than
50 mv rms ripple.
+17.1
0.1 vdc, no less than
POWER
SUPPLY
2.
500 ma, no greater than 100 mv
rms ripple.
Voltage, time accuracy, and
OSCILLOSCOPE
3.
resolution no less than 5
Rise time no greater
percent.
Sweep
than 100 nanoseconds.
periods from one microsecond
per centimeter to one second
Amplitude
per centimeter.
scales from 0,01 to 10.0 volts
per
centimeter.
Automatic
triggering,
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.