MIL-T-48593B (AR)
TABLE II.
voltages and indications (continued)
INDICATOR
REQUIRED
MEASUREMENT
OPERATION
LIT
VOLTAGE
TERMINALS
1280M switch on
1280M
+5 ±0.3 Vdc
TP12-14(+) & GND 2(-)
2560M switch on
2560M
+5 ±0.3 Vdc
TP12-15(+) & GND 2(-)
--
Target
+5 --0.3 Vdc
+
J5, Pin 6(+) &
Direction Out
J5, Pin 25(-)
--
Target
+5 --0.3 Vdc
+
J5, Pin 5(+) &
Direction In
J5, Pin 25(-)
e. With the UUT PS-1 switch and the UUT PS-2 switch in the
On position, the voltages in Table III shall be present at the
indicated points.
TABLE III.
Voltage measurements
MEASURING POINTS
VOLTAGES
+1.6 Vdc
TP10-0 (+) and UUT GND 1 (-)
+15
-1.2 Vdc
+1.6 Vdc
TP12-2 (+) and UUT GND 1 (-)
+15
-1.2 Vdc
+1.6 Vdc
TP12-3 (+) and UUT GND 1 (-)
+15
-1.2 Vdc
+1.6 Vdc
TP12-5 (+) and UUT GND 1 (-)
+15
-1.2 Vdc
+1.6 Vdc
TP11-6 (+) and UUT GND 1 (-)
+15
-1.2 Vdc
+1.6 Vdc
TP11-0 (+) and UUT GND 1 (-)
+15
-1.2 Vdc
+1.6 Vdc
TP12-0 (+) and UUT GND 1 (-)
+15
-1.2 Vdc
8.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business