MIL-T-48593B (AR)
3.5.2 Voltage distribution. with power switch, S25, in the On
position, the following voltages shall be present at the indicated
measuring points, and under the conditions specified.
a. A potential of +24.0
shall be present between
24 vdc test post (+), and GND 1 test post (-).
b. A potential of 115.0
Vac shall be present between
ACV test post and AC-RT test post.
c.
Potentials shall be present as indicated in Table I.
Voltage distribution
TABLE I.
MEASURING POINTS
SOURCE OF
INDICATION
MINUS
PLUS
VOLTAGE
+0.2 Vdc
GND l
TP 9-9
Power
+5.0
-0.0 Vdc
Jl, Pins 30,31,32 GND 1
supply 1
J2, Pins 30,31,32 GND 2
J5, Pins 30,31,32 GND 1
+15.0 +1.6 Vdc
TP 9-6
GND 1
Power
-1.2 Vdc
J5, Pins 22,23,34,35
supply 2
J5, Pins 36,37
GND 1
J1, Pins 36,37
+15.0 +1.6 Vdc
GND
l
TP 9-12
Power
-1.2 Vdc
J1, Pins 20,21
GND
1
supply 3
J5,
Pins 22,23,34,35
J5, Pins 20,21
GND
2
J2, Pins 20,21
GND 1
TP 9-11
Power
GND 2
supply 4
J2, Pins 55,56
25.0 +1.1 Vdc
GND 2
TP 9-10
Power
-1.7 Vdc
GND 2
J2, Pins 49,50
supply 5
d. With the range rate switch, and the range switch in the
manual position, the sequence tabulated in Table II shall occur as
indicated.