MIL-F-81959(AS)
(3) Motor Control Circuit - The equipment shall contain a power
supply, current regulator and control circuits to convert
3 phase, 400 Hz, 115/200 VAC to a D.C. voltage for operating
the cable maintenance fixture.
(4) Levell Wind Mechanism- The equipment shall include a level
wind mechanism to provide even wrapping of the cable on the
drum.
(5) Cable Drum- The equipment shall include an easily removable
drum for cable wrapping. The drum shall nave grooves to aid
even cable wrapping and provide more even support of the cable.
Controls - The equipment shall contain a POWER ON/OFF switch
3.5.1.6
as its single control.
3.5.1.7
Electrical Connections - Connections to external circuits
shall be provided as follows:
Receptacle
Reference
Type
Function
Designation
W1P;
MS3126F14-12P
Input Power and Control
3.5.2 Case, Cable Maintenance Fixture - The equipment shall be pro-
vided with a comb ination case which shall conform to MIL-T-21200.
Maximum Size . 17.5 inches wide by 11.5 inches high by 36.5
3.5.2.:
inches long including hardware and protective devices.
Material - Aluminum
3.5.2.:
Finish - Painted yellow, color 13538 per MIL-STD-595 and
3.5.2.;
finish per MIL-T-21200.
- The weight of the case shall not exceed 45 pounds.
3.5.2.4 Weight
3.6 Design Date - to data is required by this specification
(other than
ports accompanying samples submitted for testing) or applicable
documents, unless specified in the contract or order (see paragraph 6.7).
Workmanship - Workmanship shall be in accordance with MIL-
3.7
STD-454, Req. 9.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business